Friday, March 26, 2010

Choosing the Right Underground Pipe for Your Outdoor Wood Furnace (Part 2):

Click here to read Part 1

First, foam insulated underground piping is almost always 1 inch pex. As discussed in a previous article 1 inch pex carries far fewer BTU's than pipe with a true 1 inch inside diameter such as Pex-al-pex pipe. Expansion should also be taken into account. 100 feet of underground pex heated up to 180°F will expand 6 to 7 inches lengthwise. This puts pressure on fittings and may cause leaks or failures.

The insulation itself should also be considered. Piping used for supplying heat from a hot water source, such as an outdoor wood furnace, lose heat in 3 ways: Convection, Radiation and Conduction. Convection is air moving across a surface similar to a radiator or heat-sync. Radiation is heat moving from hot to cold, like we all learned about in high school physics. Conduction, related to convection and radiation has to do with how heat moves through materials like air, foam or metal (electrical wiring).

Convection doesn’t apply when outside air is sealed off. R-value, a measure of convection, means little when convection is absent.

Radiant heat loss is the most relevant when speaking of underground insulated pipe. We’ll return to this shortly.

Conduction, heat transferred away by the materials surrounding it, is best controlled by wisely choosing the proper materials for insulation.

Foam filled underground pipe use urethane-based foams that limit heat loss based strictly on R-value, trying to limit how much heat is lost to convection. Foams only limit radiant heat loss by absorbing heat in a slightly limited way.

The best choice for underground lines is a pipe incorporates both foam and foil wrapped insulation. The foil wrapping retains over 97% of the radiant energy back into the pipe, virtually eliminating heat loss. Foil wrap must be contained. Strong, flexible corrugated pipe provides a shell of protection for the foil wrap and also creates a space of dead air that serves as a conductive break. Having the correct corrugated pipe is important, too stiff and it will crack when bent or compressed, too thin and it may be pierced by rocks or other sharp objects in the ground. After installation this type of underground pipe, expanding foam is used on each end to seal the air space, eliminating heat loss by convection.

Hawken Energy carries Heat-Miser foam/foil-wrapped pex-al-pex underground pipe through our Factory Rep network and through our online store. Heat-Miser pipe is recommended for all Hawken Energy installations. It is available in rolls 250 feet long and can be cut to length for your installation at increments of 25 feet.

For more information visit us online or contact your local Hawken Energy Factory Rep.


Posted by Don Squire